OVERVIEW
The Compact Door Interface Unit (DIU 200) is designed primarily to provide power
to a door lock, as well as local power to a CEM reader when a high level of security
is required. It has onboard inputs which can be used to monitor conditions such as
a fire alarm or activated break-glass condition.
The DIU 200 improves door security, by allowing the installer to locate lock
controls on the secure side of a door, with an intelligent CEM reader on the
unsecured side. The DIU 200 communicates with an intelligent CEM reader over
a single pair RS485 cable. Upon a valid swipe at the card reader, the reader
will instruct the DIU (over the RS485 communications channel) to activate the
appropriate output to release the lock using a coded data signal (i.e. coded lock).
As an added benefit, the DIU 200 monitors the status of all standard door
monitoring inputs; inputs on an intelligent CEM reader are free for use as general
purpose inputs.
DIU 200 Module
• DoorInterfaceElectronics
held on one board
• Provides‘codedlock’serial
interface between door
hardware and card reader
• Onsiteselectablefor12or
24 volt lock output
• Firealarmandbreakglass
inputs for emergency door
release
• Designedforease
of installation and
maintenance using 2 part
connectors throughout
• CompliantwithEN55022
(emissions)andEN55024
(access control immunity)
• Backupbatteryconnection
for emergency power
(optional)
FEATURES
DIU 200 Module
Compact Door Interface Unit
1.DIUUnitEnclosure
2. CEM Reader
3. Sounder
4.BreakGlassUnit
5. REX/ Exit Reader or
Secure side push button
6.DoorHolder(viaoptionalBackplane)
7. Door Lock
8. Lock Sense
9.DoorPositionsensor
Vista de página 0
1 2

Resumo do Conteúdo

Página 1 - DIU 200 Module

www.cemsys.comOVERVIEWThe Compact Door Interface Unit (DIU 200) is designed primarily to provide power to a door lock, as well as local power to a CEM

Página 2 - TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONSPHYSICALSize 115x76x10mm(4.5x3.0x0.4”)Weight 0.1KgPower-Voltage 12Vdc - Current 30mA (excluding locks and h